{"id":21535,"date":"2023-06-26T18:48:15","date_gmt":"2023-06-26T09:48:15","guid":{"rendered":"https:\/\/www.c-technol.co.jp\/en\/wp\/?page_id=21535"},"modified":"2025-03-27T19:17:50","modified_gmt":"2025-03-27T10:17:50","slug":"personalmonitoring","status":"publish","type":"page","link":"https:\/\/www.c-technol.co.jp\/en\/dosimetryequipment\/personalmonitoring\/","title":{"rendered":"Personal Monitoring System"},"content":{"rendered":"<section class=\"personalmonitoring01\">\n<div class=\"container\">\n<p class=\"personalmonitoring01_ttl01 common_ttl15\" id=\"subContainerMarginBase\"><span>Dosimetry Equipment<\/span><\/p>\n<h2 class=\"personalmonitoring01_ttl02 common_ttl14\">Personal Monitoring System<\/h2>\n<figure class=\"personalmonitoring01_img01\">\n      <picture><source type=\"image\/webp\" srcset=\"..\/..\/images\/dosimetryequipment\/personalmonitoring\/personalmonitoring01_img01.webp 1x, ..\/..\/images\/dosimetryequipment\/personalmonitoring\/personalmonitoring01_img01@2x.webp 2x\" \/><img decoding=\"async\" src=\"..\/..\/images\/dosimetryequipment\/personalmonitoring\/personalmonitoring01_img01.png\" alt=\"Personal Monitoring System\" \/>\n      <\/picture>\n    <\/figure>\n<h3 class=\"personalmonitoring01_txt01 common_txt06\">The Personal Monitoring System was developed in collaboration with IRSN of France, achieving world-class performance.<\/h3>\n<p><small><sup>\uff0a<\/sup>The dosimetry service of IRSN has been integreted to Alternative Energies and Atomic Energy Commission (CEA) since January 1st 2025.<\/small><\/p>\n<h3 class=\"personalmonitoring01_ttl03 common_ttl04\">Advantages<\/h3>\n<ul class=\"personalmonitoring01_list01 common_list16\">\n<li>\n<p class=\"common_txt01\">The advantages of glass enable accurate measurement.<\/p>\n<\/li>\n<li>\n<p class=\"common_txt01\">Up to 2000 glass detectors can be read continuously to realize high throughput<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"personalmonitoring01_ttl04 common_ttl04\">Specifications<\/h3>\n<table class=\"personalmonitoring01_table01 common_table02\">\n<tr>\n<th>Measured radiation type<\/th>\n<td>Photons and beta particles<\/td>\n<\/tr>\n<tr>\n<th>Measured energy range<\/th>\n<td>Photons: 10 keV to 10 MeV<br \/>Beta: 140 keV to 3 MeV<\/td>\n<\/tr>\n<tr>\n<th>Measured dose range<\/th>\n<td>50 \u03bc Sv &#8211; 10 Sv<\/td>\n<\/tr>\n<tr>\n<th>Dose reproducibility<\/th>\n<td>Within 5% at 100 \u03bc Gy<br \/>Within 2% at 1 mGy<\/td>\n<\/tr>\n<tr>\n<th>Automatic calibration function<\/th>\n<td>A dose conversion coefficient can be obtained by reading a standard dosimeter* of known dose.<br \/><span class=\"color01\">* Standard dosimeters must be prepared by each user <\/span><\/td>\n<\/tr>\n<\/table>\n<h3 class=\"personalmonitoring01_ttl05 common_ttl04\">Applications<\/h3>\n<ul class=\"personalmonitoring01_list02 common_list16\">\n<li>\n<p class=\"common_txt01\">Personal dosimetry<\/p>\n<\/li>\n<\/ul>\n<h3 class=\"personalmonitoring01_ttl06 common_ttl04\">Brochure<\/h3>\n<div class=\"personalmonitoring01_btn01 common_btn06 color01\">\n      <a href=\"..\/..\/pdf\/Dosimetry_Personal_Monitoring_System.pdf\" target=\"_blank\" rel=\"noopener\"><span>Personal Monitoring System [PDF]<\/span><\/a>\n    <\/div>\n<h3 class=\"personalmonitoring01_ttl07 common_ttl04\">Inquiry<\/h3>\n<div class=\"personalmonitoring01_btn02 common_btn05\">\n      <a href=\"..\/..\/\/inquiry\"><span>Contact Us<\/span><\/a>\n    <\/div>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Dosimetry Equipment Personal Monitoring System The Personal Monitoring System was developed in collaboration with IRSN of France, achieving world-class performance. \uff0aThe dosimetry service of IRSN has been integreted to Alternative Energies and Atomic Energy Commission (CEA) since January 1st 2025. Advantages The advantages of glass enable accurate measurement. Up to 2000 glass detectors can be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":252,"menu_order":14,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-21535","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/pages\/21535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/comments?post=21535"}],"version-history":[{"count":11,"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/pages\/21535\/revisions"}],"predecessor-version":[{"id":21808,"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/pages\/21535\/revisions\/21808"}],"up":[{"embeddable":true,"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/pages\/252"}],"wp:attachment":[{"href":"https:\/\/www.c-technol.co.jp\/en\/wp-json\/wp\/v2\/media?parent=21535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}